PBD Series overdrive strobe controller

PBD Series overdrive strobe controller


Precise control of light source lighting time, short output response time.      
Integrated continuous and strobe lighting functions to meet the requirements of different application scenarios.         
Trigger delay time and light source delay time can be set to better synchronize with the camera.





 
Model PBD-12048-4-LS/LSE PBD-12048-6-LS/LSE
Lighting method Continuous / trigger lighting 
Drive method Constant voltage
Intensity Control PWM / Current control 
No of Channels 4 6
PWM frequency C-0 62.5KHz, C-1 125KHz, C-2 250KHz, C-3 450KHz 
Error detection display Front digital display
Over current protection Current over 110% protection. Reset after turning the power off and on again. 
Input Voltage AC100-240V   50/60Hz
Trigger method Outer trigger (Two-way input, regardless of polarity)
Input Voltage DC 24V
Output 24V 5V
Intensity Control PWM  Current control 
Trigger input voltage DC12~24V 7-12mA
Trigger output voltage DC12V 20mA max
Output power (rated) Constant lighting 60W Max
Output voltage DC 22V / DC48V 
Output current (strobe) Single CH 25A max 
Output current (continuous) Single CH 2.5A max 
Trigger response delay 2us Max
Strobe light time 1~999ms adjustable
Light time delay 0~999us adjustable
Trigger output time 1~999us adjustable
Trigger output delay time 0~500us adjustable
Light brightness  0~255 steps
Weight (kg) 1.3 1.36
Dimension (mm) 130.8x116.7x1677.8
Working environment Temperature -10~50℃ / Humidity 20~85% RH (with no condensation)
Storage environment Temperature -20~65℃ / Humidity 20~85% RH (with no condensation)
Cooling method  Forced air (Fan)
Material surface treatment SPCC painting
Communication RS232 / 100M ethernet (optional)
Optional Accessory AC cord, Internet cable LSE-10/1000M-3, LS-232-3-B communication cable, extension cable
PBD -120 48 -4 LS/LSE
Model Power Output Voltage Channel No. Communication 
Communication parameter
Protocol Working mode Communication
 speed
Transport format
RS-232 /EIA-485 Half-duplex mode 19200bps Start bit Data bit Check bit Stop bit
1 8 0 1

Controller External Trigger Definition
Trigger Port No Trigger definition Input voltage Trigger Port No Trigger definition Input voltage
C Trigger  input share   N Trigger output share -  
1  Trigger Input +    1  Trigger output +   
2  Trigger Input -   2  Trigger output +  
3  Trigger Input +  DC12-24V 3  Trigger output  + DC12V
4  Trigger Input -   4  Trigger Input  +  
5  Trigger Input +    5  Trigger Input +   
6  Trigger Input -   6  Trigger Input  +  

                                                            
Ethernet cable           
"It is recommended to use high-speed super Class 6 double-shielded network cable SF/UTP-6A,
which is within 50M in length."

 