PBT4 Series Strobe Controller

PBT4 Series Strobe Controller


Strobe lighting. Increase brightness for three times.     
RS-232/EIA-485 communication protocol for selection.        
Can setting lighting delay time and trigger output delay time.
 



Model PBT4-20048-27-LS/EIA-A      
No of Channels 27      
Error detection display LED display OCP      
Over current protection LED display OCP. Reset after turning the power off and on again.       
Input voltage AC100-240V      
Trigger method Outer trigger (Bidirectional input, regardless of polarity)      
Trigger input voltage DC5-24V      
Output voltage DC48V      
Max Output Current  10A       
Trigger lighting delay < 5us       
Strobe light time IDFront pannel and software setting 0-99      
Strobe light time 0~999ms adjustable      
Light time delay 0~200us adjustable      
Light brightness  0~255       
Trigger mode Inner trigger and outer trigger       
Communication RS232 / 485      
Weight 2.34KG      
Dimension(mm 259.5X241X98.5      
Working environment Temperature -10~50 / Humidity 20~85% RH (with no condensation)      
Storage environment Temperature -20~65 / Humidity 20~85% RH (with no condensation)      
Cooling method Forced air (Fan)      
Material SPCC steel plate with painting      
Accessory AC cord, EIA-485-3-B,
LS-232-3-B communication able, extension cable
 

 
PBT4 -200 48 -27  LS/EIA   A
Model Power Output Voltage Channel No. Communication    Edition
1. Communication parameter
Protocol Working mode Communication
 speed
Transport format
RS-232 /EIA-485 Half-duplex mode 19200bps Start bit Data bit Check bit Stop bit
1 8 0 1

Controller External Trigger Definition (PBT4-20048-27 Series)
Trigger  Port No Trigger  Definition  
C Trigger Input Common  
1 1ch Trigger Input  
2 2ch Trigger Input  
3 3ch Trigger Input  
4 4ch Trigger Input (Bidirectional input,
5 5ch Trigger Input  regardless of polarity)
6 6ch Trigger Input  
 
26 26ch Trigger Input  
27 27ch Trigger Input  





 